Outcomes of Cardiac Resynchronization Therapy With or Without Defibrillation in Patients With Nonischemic Cardiomyopathy.

Leyva, Francisco and Zegard, Abbasin and Acquaye, Edmund and Gubran, Christopher and Taylor, Robin and Foley, Paul W X and Umar, Fraz and Patel, Kiran and Panting, Jonathan and Marshall, Howard and Qiu, Tian (2017) Outcomes of Cardiac Resynchronization Therapy With or Without Defibrillation in Patients With Nonischemic Cardiomyopathy. Journal of the American College of Cardiology, 70 (10). pp. 1216-1227. ISSN 1558-3597. This article is available to all HEFT staff and students via ASK Discovery tool http://tinyurl.com/z795c8c by using their HEFT Athens login IDs

Full text not available from this repository.
Official URL: https://www.clinicalkey.com/#!/content/journal/1-s...

Abstract

BACKGROUND

Recent studies have cast doubt on the benefit of cardiac resynchronization therapy (CRT) with defibrillation (CRT-D) versus pacing (CRT-P) for patients with nonischemic cardiomyopathy (NICM). Left ventricular myocardial scar portends poor clinical outcomes.

OBJECTIVES

The aim of this study was to determine whether CRT-D is superior to CRT-P in patients with NICM either with (+) or without (-) left ventricular midwall fibrosis (MWF), detected by cardiac magnetic resonance.

METHODS

Clinical events were quantified in patients with NICM who were +MWF (n = 68) or -MWF (n = 184) who underwent cardiac magnetic resonance prior to CRT device implantation.

RESULTS

In the total study population, +MWF emerged as an independent predictor of total mortality (adjusted hazard ratio [aHR]: 2.31; 95% confidence interval [CI]: 1.45 to 3.68), total mortality or heart failure hospitalization (aHR: 2.02; 95% CI: 1.32 to 3.09), total mortality or hospitalization for major adverse cardiac events (aHR: 2.02; 95% CI: 1.32 to 3.07), death from pump failure (aHR: 1.95; 95% CI: 1.11 to 3.41), and sudden cardiac death (aHR: 3.75; 95% CI: 1.26 to 11.2) over a maximum follow-up period of 14 years (median 3.8 years [interquartile range: 2.0 to 6.1 years] for +MWF and 4.6 years [interquartile range: 2.4 to 8.3 years] for -MWF). In separate analyses of +MWF and -MWF, total mortality (aHR: 0.23; 95% CI: 0.07 to 0.75), total mortality or heart failure hospitalization (aHR: 0.32; 95% CI: 0.12 to 0.82), and total mortality or hospitalization for major adverse cardiac events (aHR: 0.30; 95% CI: 0.12 to 0.78) were lower after CRT-D than after CRT-P in +MWF but not in -MWF.

CONCLUSIONS

In patients with NICM, CRT-D was superior to CRT-P in +MWF but not -MWF. These findings have implications for the choice of device therapy in patients with NICM.

Item Type: Article
Additional Information: This article is available to all HEFT staff and students via ASK Discovery tool http://tinyurl.com/z795c8c by using their HEFT Athens login IDs
Subjects: WG Cardiovascular system. Cardiology
Divisions: Emergency Services > Cardiology
Related URLs:
Depositing User: Mrs Caroline Tranter
Date Deposited: 24 Nov 2017 14:21
Last Modified: 24 Nov 2017 14:21
URI: http://www.repository.heartofengland.nhs.uk/id/eprint/1515

Actions (login required)

View Item View Item